M.T.H. H9 2-8-0Steam Locomotive Manuel de l'opérateur Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 31
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
H9 2-8-0 Steam Locomotive
21
If you experience poor or no smoke output when the smoke unit is on and has
fluid, check the wick to see if it has become hard, blackened, and unabsorbent
around the heating element. To remove the smoke unit you will first have to
remove the boiler shell (by removing the body mounting screws shown in Fig. 9 on
pg. 15), board and bracket that block the smoke unit assembly from being accessed.
To do this, follow these instructions:
1. Unplug the two wiring harnesses from the board mounted to the inside of the
boiler and behind the smoke unit.
2. Remove the two screws securing the smoke unit inside the shell as seen in Fig. 17.
3. With the board free of the mounting screws, slide the assembly out of the boiler
as seen in Fig. 18.
4. Once the unit is freed, remove the inspection cover (Fig. 18). Inspect the wick; if
it is darkly discolored and hard, it should be replaced.
Replacement parts and wick replacement instructions are available directly from
the M.T.H. Parts Department phone: 410-381-2580; e-mail: parts@mth-
railking.commail: 7020 Columbia Gateway Drive, Columbia MD 21046-1532
Figure 17 Figure 18
Remove Screw to Inspect Unit,
then turn Unit over to inspect.
Inspection Cover Screws
Vue de la page 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 30 31

Commentaires sur ces manuels

Pas de commentaire